Immersion cooling tank suppliers
The companies that sell the tank and its cooling loop: Submer, GRC, Vertiv, LiquidStack, Asperitas, DCX, Midas and more, each with a named system and its published kW rating.
18 companies · checked
| Asperitas | Tank systems | Single-phase | DFCX1 | 601 | 2026-11-11 |
|---|---|---|---|---|---|
| Baltimore Aircoil Company | Tank systems | Single-phase | COBALT / CorTex immersion tank | 1501 | 2026-11-11 |
| DCX Liquid Cooling Systems | Tank systems | Single-phase | H1000 | 801 | 2026-11-11 |
| Delta Electronics | Tank systems | Two-phase | Delta Two-phase Immersion Cooling | 1001 | 2026-11-11 |
| DUG Technology | Tank systems | Single-phase | DUG Cool 26 RU tank | 301 | 2026-11-11 |
| Envicool | Tank systems | Both | Coolinside TK42D100F3 | 1001 | 2026-11-11 |
| Fujitsu | Tank systems | — | Fujitsu Server PRIMERGY Liquid Immersion Cooling System (launched Sept 2018) | — | 2026-11-11 |
| GIGABYTE / Giga Computing | Tank systems | Single-phase | A1P0-EA0 12U tank | 401 | 2026-11-11 |
| GRC | Tank systems | Single-phase | ICEraQ SX / FLEX (Duo, Quad) | 3681 | 2026-11-11 |
| Immersion4 | Tank systems | — | DTM (Dynamic Thermal Management) immersion datacenter technology | — | 2026-11-11 |
| LiquidStack | Tank systems | Both | DataTank 4U / 48U | 63 | 2026-11-11 |
| Midas Immersion Cooling | Tank systems | — | 50U MIDAS XCI | 1501 | 2026-11-11 |
| Mitsubishi Heavy Industries | Tank systems | — | 12-ft container data center with hybrid immersion and air cooling | — | 2026-11-11 |
| Submer | Tank systems | Single-phase | SmartPod EXO / EVO | 3611 | 2026-11-11 |
| Sugon DataEnergy | Tank systems | Two-phase | C8000 V3.0 MW-class phase-change immersion cabinet and infrastructure solution | 9001 | 2026-11-11 |
| TMGcore (Airedale by Modine) | Tank systems | — | EdgeBox 10 (TMGcore EdgeBox range) | 101 | 2026-11-11 |
| Vertiv | Tank systems | — | Vertiv CoolCenter Immersion (24U self-contained; 42U/52U tanks with CDU) | 2401 | 2026-11-11 |
| Wiwynn | Tank systems | Both | Two-phase immersion tank; Intel Open IP single-phase tank study | — | 2026-11-11 |
What does a tank power rating tell you?
Each kW figure belongs to one named model and its water conditions. GRC rates its ICEraQ CDU at 368 kW on 13°C water; DUG rates its standard tank at 30 kW on a 29.5°C loop. Compare models at matching water temperatures, then ask each supplier for the rating at your facility water temperature.
Open a company page for the rating basis, hardware evidence and dated sources. Read the field definitions or compare companies side by side.